IPP Logo

Innovative Process Solutions
TEMPERATURE TRANSMITTERS
Temperature transmitters feature significant advances over the direct wired counterparts
- Eliminate special cabling requirements
- Simplify engineering and maintenance
- Enable advanced diagnostics
YTA110

YTA Series

YTA Series temperature transmitters convert the sensor signals to a unified signal, 4 to 20mA signal or FOUNDATION™ fieldbus. This eliminates the drawbacks of wire resistance and signal noise that are often experienced with conventional temperature instruments, which must be connected by long extension lead wires or three-conductor cables to converters in an instrument panel room.

An additional feature is that both the sensor type and the measurement range can be selected.

communication protocols

TÜV certified SIL 2 for single use in standard configuration and robust dual-compartment housing to harsh environment

YTA50

YTA50 Temperature Transmitter

The YTA50 and YTA70 are head mount type of temperature transmitters that conform to the standard DIN formB head mounting.

Hart

Top of Page

YTA70

YTA70 Temperature Transmitter

The YTA50 and YTA70 are head mount type of temperature transmitters that conform to the standard DIN formB head mounting.

Hart

Top of Page

VK616

SINEAX VK616

Head Transducer, RTD/TC Inputs, 2-wire, for Sensors, programmable, Ex/NEx

The SINEAX VK616 is for installation into terminal housings at temperature sensors per DIN 43 729, type B.

VK616 converts the measured quantity (i.e. signal from a thermocouple or a resistance thermometer) into a proportional, analog output quantity.

  • Measured quantity and measuring range can be programmed with a PC: facilitates planning and project work, short lead-times, minimal inventory
  • Integrated cold junction compensation
  • Measurement output: 4 to 20 mA, 2-wire connection
  • Optionally available with or without electrical isolation between input and output: prevents measurement value distortion caused by potential transfer
  • Open-circuit sensor and short-circuit monitoring / defined output performance in the event of disturbance
  • With or without auxiliary power terminals (prog. from 12 to 30 V)
  • Terminals with captive screws
  • Available with "intrinsically safe" expl. protection (EEx ia IIC T6)
  • Serial interface

Top of Page

VK626

SINEAX VK626

Head Transducer, RTD/TC Inputs, 2-wire, HART, for Sensors, progammable, Ex/NEx

For installation in the terminal head of a temperature sensor DIN 43 729, shape B.
For use in process control systems (SPC, PLC). The SINEAX VK 626 converts the measured quantity (i.e. signal from a thermocouple or resistance thermometer) into a proportional, analog output quantity.

  • Digital communication and power supply via the 2-wire output line
  • Measured quantity, measuring range and other parameters programmable with PC, suitable HART interface and appropriate software
  • Electrical isolation between input and output: prevents measurement value distortion caused by potential transfer
  • Measurement output: 4 to 20 mA, 2-wire connection
  • Open-circuit sensor and short-circuit monitoring / defined output performance in the event of disturbance
  • Terminals with captive screws
  • Available with "intrinsically safe" explosion protection per EEx ia IIC T6
  • Interface: output terminals

Top of Page

 

 

 

 

 

Camille Bauer

 

 

 

 

 