TEMPERATURE TRANSMITTERS
Temperature transmitters feature significant advances over the direct wired counterparts
- Eliminate special cabling requirements
- Simplify engineering and maintenance
- Enable advanced diagnostics
 |
YTA Series
YTA Series temperature transmitters convert the sensor signals to a unified signal, 4 to 20mA signal or FOUNDATION™ fieldbus. This eliminates the drawbacks of wire resistance and signal noise that are often experienced with conventional temperature instruments, which must be connected by long extension lead wires or three-conductor cables to converters in an instrument panel room.
An additional feature is that both the sensor type and the measurement range can be selected.

TÜV certified SIL 2 for single use in standard configuration and robust dual-compartment housing to harsh environment |
 |
YTA50 Temperature Transmitter
The YTA50 and YTA70 are head mount type of temperature transmitters that conform to the standard DIN formB head mounting.

Top of Page |
 |
YTA70 Temperature Transmitter
The YTA50 and YTA70 are head mount type of temperature transmitters that conform to the standard DIN formB head mounting.

Top of Page |
 |
SINEAX VK616
Head Transducer, RTD/TC Inputs, 2-wire, for Sensors, programmable, Ex/NEx
The SINEAX VK616 is for installation into terminal housings at temperature sensors per DIN 43 729, type B.
VK616 converts the measured quantity (i.e. signal from a thermocouple or a resistance thermometer) into a proportional, analog output quantity.
- Measured quantity and measuring range can be programmed with a PC: facilitates planning and project work, short lead-times, minimal inventory
- Integrated cold junction compensation
- Measurement output: 4 to 20 mA, 2-wire connection
- Optionally available with or without electrical isolation between input and output: prevents measurement value distortion caused by potential transfer
- Open-circuit sensor and short-circuit monitoring / defined output performance in the event of disturbance
- With or without auxiliary power terminals (prog. from 12 to 30 V)
- Terminals with captive screws
- Available with "intrinsically safe" expl. protection (EEx ia IIC T6)
- Serial interface
Top of Page |
 |
SINEAX VK626
Head Transducer, RTD/TC Inputs, 2-wire, HART, for Sensors, progammable, Ex/NEx
For installation in the terminal head of a temperature sensor DIN 43 729, shape B.
For use in process control systems (SPC, PLC). The SINEAX VK 626 converts the measured quantity (i.e. signal from a thermocouple or resistance thermometer) into a proportional, analog output quantity.
- Digital communication and power supply via the 2-wire output line
- Measured quantity, measuring range and other parameters programmable with PC, suitable HART interface and appropriate software
- Electrical isolation between input and output: prevents measurement value distortion caused by potential transfer
- Measurement output: 4 to 20 mA, 2-wire connection
- Open-circuit sensor and short-circuit monitoring / defined output performance in the event of disturbance
- Terminals with captive screws
- Available with "intrinsically safe" explosion protection per EEx ia IIC T6
- Interface: output terminals